{"ok":true,"site":{"host":"chronophys-webmcp-gateway.vercel.app","url":"https://chronophys-webmcp-gateway.vercel.app/","type":"live","desc":"Next.js Agentic Application natively integrated with W3C WebMCP (document.modelContext) standard.","tools":[{"name":"query_catalog","kind":"answer","impl":"imperative","description":"Searches, filters, and ranks items in the enterprise catalog based on keyword, category, price threshold, and stock availability.","inputSchema":{"type":"object","properties":{"keyword":{"type":"string","description":"Search term to match against name, description, features, or technical specifications."},"category":{"type":"string","description":"Filter by specific category.","enum":["all","industrial","ai-edge","sensors","consulting"]},"maxPrice":{"type":"number","description":"Maximum allowable price in USD."},"inStockOnly":{"type":"boolean","description":"When true, excludes items that are currently out of stock or have long lead times."},"maxResults":{"type":"number","description":"Maximum number of items to return (default: 5)."}},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"execute_action","kind":"act","impl":"imperative","description":"Triggers UI state actions such as autofilling customer forms, selecting catalog items, filtering views, or switching accessibility Grandma Mode.","inputSchema":{"type":"object","properties":{"actionType":{"type":"string","description":"The target action to perform.","enum":["FILTER_CATALOG","SELECT_ITEM","AUTOFILL_FORM","SUBMIT_FORM","CLEAR_FORM","TOGGLE_GRANDMA_MODE","RESET_STATE"]},"payload":{"type":"object","description":"The parameter payload specific to the actionType (e.g., form fields, itemId, category)."}},"required":["actionType"]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"AUTOFILL_FORM","kind":"act","impl":"imperative","description":"Directly autofills the Enterprise Request for Quote (RFQ) customer form with contact information, urgency level, and technical notes.","inputSchema":{"type":"object","properties":{"customerName":{"type":"string","description":"Customer full name."},"email":{"type":"string","description":"Corporate contact email."},"company":{"type":"string","description":"Plant or organization name."},"urgencyLevel":{"type":"string","enum":["low","standard","emergency"],"description":"Dispatch urgency."},"notes":{"type":"string","description":"Technical telemetry notes or machinery specs."},"itemId":{"type":"string","description":"Optional product ID to select."}},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"TOGGLE_GRANDMA_MODE","kind":"act","impl":"imperative","description":"Toggles high-contrast Grandma Mode accessibility with 48px+ touch targets, bold borders, and enlarged text.","inputSchema":{"type":"object","properties":{},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"TRIGGER_EMERGENCY_THROTTLE","kind":"act","impl":"imperative","description":"Autonomous closed-loop safety interlock that commands the variable-frequency drive (VFD) via Modbus TCP to safely throttle machine RPM to 300 RPM upon critical ISO Zone-D vibration.","inputSchema":{"type":"object","properties":{"targetRpm":{"type":"number","description":"Safe glide target RPM (default: 300)"},"reason":{"type":"string","description":"Fault cause triggering closed-loop throttle"},"modbusRegister":{"type":"string","description":"VFD Speed Reference Register (40001)"}},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"GENERATE_MAINTENANCE_AUDIT","kind":"act","impl":"imperative","description":"Compiles current optical Phase-EVM telemetry, modal frequencies, and mechanical fault logs into an ISO 17025 SHA-256 signed maintenance audit report.","inputSchema":{"type":"object","properties":{"equipmentId":{"type":"string","description":"Equipment asset identifier (e.g. TURBOPUMP-04)"},"signOffAnalyst":{"type":"string","description":"ISO 18436 Certified Vibration Analyst Name"}},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"record_demo","kind":"act","impl":"imperative","description":"Programmatically triggers a 30-second synchronized multi-modal optical EVM and telemetry MP4 recording with metadata burn-in.","inputSchema":{"type":"object","properties":{"durationSeconds":{"type":"number","description":"Duration of the recording in seconds (default: 30)"},"targetRoi":{"type":"string","description":"Target region of interest (e.g. Drive-End Bearing)"}},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"generate_pdf_report","kind":"act","impl":"imperative","description":"Programmatically compiles current modal FFT spectrum, ISO 10816-3 severity, and phase EVM telemetry into a signed ISO 17025 PDF audit certificate.","inputSchema":{"type":"object","properties":{"equipmentId":{"type":"string","description":"Equipment asset identifier (e.g. TURBOPUMP-04)"},"analyst":{"type":"string","description":"Certified vibration analyst name"}},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"toggle_ai_specialist","kind":"act","impl":"imperative","description":"Opens or closes the contextual Gemini-powered AI Vibration Specialist dialog with real-time root cause analysis.","inputSchema":{"type":"object","properties":{"open":{"type":"boolean","description":"True to open modal, false to close"},"initialQuery":{"type":"string","description":"Optional initial prompt/question for the AI specialist"}},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"auto_lock_components","kind":"act","impl":"imperative","description":"Toggles automatic optical ROI component locking (Stator, Drive-End Bearing, Shaft Coupling, Pump Impeller) and sub-band spatial filters.","inputSchema":{"type":"object","properties":{"enableTracking":{"type":"boolean","description":"Enable or disable automatic component tracking"}},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"set_evm_parameters","kind":"act","impl":"imperative","description":"Programmatically configures Phase-EVM motion magnification parameters: alpha gain factor, frequency bandpass filters, and machine RPM.","inputSchema":{"type":"object","properties":{"alpha":{"type":"number","description":"Motion magnification amplification factor (5 to 100)"},"fLow":{"type":"number","description":"Lower frequency bandpass cutoff in Hz"},"fHigh":{"type":"number","description":"Upper frequency bandpass cutoff in Hz"},"shaftRpm":{"type":"number","description":"Nominal machine shaft speed in RPM"}},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"},{"name":"get_agent_state","kind":"answer","impl":"imperative","description":"Retrieves current live web application context, total registered tools, active accessibility settings, and available action types.","inputSchema":{"type":"object","properties":{},"required":[]},"hasHandler":true,"hasExecute":false,"__source":"spec","executable":false,"handlerField":"handler"}],"category":"Productivity & Business","apiSurface":"spec","toolCount":12}}